When portable ladders are used for access to an upper landing surface the ladder side rails shall extend at least 3 feet 9 m above the upper landing surface to which the ladder is used to gain access.
Ladder extend above roof.
For parapet ladders the access level is.
Tie the top at support points.
Parapet ladders must have an access level at the roof if the parapet is cut to permit passage through it.
Remember it should extend at least 3 feet above the roof s edge.
A ladder top should extend at least above the roof edge of a building when used as access to the roof of a building.
When you re working with an extension ladder for roofing you need it to extend at least three feet above the roof line.
Or when such an extension is not possible because of the ladder s length then the ladder shall be secured at its top to a rigid support that will not deflect and a grasping device such as a grabrail shall be provided to assist employees in mounting and dismounting the ladder.
The side rails of through or sidestep ladders extend at least 42 inches 1 1 m above the top of the access level or landing platform served by the ladder.
1917 118 d 7 ladders whose pitch exceeds 90 degrees to the horizontal slanting backward on the climbing side shall not be used.
When you get off the roof take the same approach holding onto the ladder and stepping around it instead of over the top.
If the parapet is continuous the access level is the top of the parapet.
Roofing ladder a roofing ladder is simply an extension ladder that has been securely attached to the ridge of a sloped roof to allow a roofer to work from an angle though no more than 75 degrees on the roof.
This is much more than most people will realize but a full three feet or 36 inches is necessary for a safe ladder set up.
This gives the ladder some leeway and will help keep it from moving out of place as you re climbing.
Side rails of through or side step fixed ladders must extend 42 inches 1 1 m above the top level or landing platform served by the ladder.
To secure the extending roof ladder a pair of roof hooks should be installed onto the ladder.
The side rails of ladders shall extend at least 36 inches 0 91 m above the top landing surface unless grab bars or equivalent holds are provided.
1 when portable ladders are used for access to an upper landing surface the ladder side rails shall extend at least 3 feet 9 m above the upper landing surface to which the ladder is used to gain access.
Or when such an extension is not possible because of the ladder s length then the ladder shall be secured at its top to a rigid support that will not deflect and a grasping device such as a grabrail shall be provided to assist employees in mounting and dismounting the ladder.
Brace or tie off the ladder near the base.
1910 23 d 4 i the roof if the parapet is cut to permit passage through the parapet.
Use care when getting on and or off the ladder at the top or bottom in order to avoid tipping the ladder over sideways or causing the ladder base to slide.